Packed With Power
"I
don't want to compromise on power. I love firing
fronts, sometimes 1200 feet across with hundreds
of pieces of product. I use specialized equipment
to really punch out the power in those cases.
Other times, it's just a string of 20 or even
30 shells going up at once, and for that I usually
have to chain them with quick match. How would
you handle it?"
Firelinx
firing modules operate at 30 Volts, offering
15 e-matches in series, 10 parallel (at 2 Ohms/match).
At 1.6 Ohms/match, worst case is 18/10. At the
same time, the modules are incredibly small:
only about a 5" cube. This is accomplished
by using Capacitive Discharge. Our high power
circuit requires no recharge between cues and
all cues may be fired simultaneously - not just
within one module, but also across all the modules
in the field. It's expensive and heavy to try
to get 30 volts out of batteries. The
Firelinx Firing Module uses a charge pump to
boost the 6V of battery power to 30V in the
capacitor bank. That makes 160 amperes of current
available at a moment's notice to fire the e-matches.
Most users don't realize that the worst-case
scenario for a battery is a lot of e-matches
connected in series. Batteries like parallel
wiring because they have a lot of current, but
their lower voltage makes it impossible to push
through a number of series-wired matches. Capacitive
discharge systems are just the opposite. CD
firing has high voltage, so it's fine with series
connections, but it has to protect the amount
of charge on the capacitors, so the CD firing
circuits have current limits - usually 5 Amperes.
This is lower than the 20A you might be able
to get with a straight battery connection. For
fronts, this means that each firing module can
break 480 e--matches, and you can put as many
of them as necessary across the front, as each
can fire at the same instant. This also minimizes
the long wiring runs across the front. When
more than 15 e-matches are needed on a single
cue the system simply splits the cue, with 15
on one string and 15 on the other, both firing
at the same time.
"I
want to do huge fronts, maybe a thousand E-matches.
My current system has to ripple fire anything
that big."
All
modules will fire at the same instant of time
for fronts or split-cue wiring. Not only can
all modules fire at the same instant, but also
because of our high power rating, we can fire
480 e-matches off one module. This means you
could do 1,440 matches with only three modules.
"I've
had trouble with series-wired e-matches, particularly
the cheap ones, not all firing in series connections,
so I've started wiring more in parallel. I've
also done some measurements and sometimes the
cheap matches don't fire until 15 or 17 milliseconds
after the current is applied. I'm not making
a lot of money; I'd love to use cheaper matches,
but not if they're going to cost me the show."
The Firelinx Firing Module has over 60 Joules
of energy storage in the capacitor bank. This
is enough to fire every cue for up to 20mS.
In addition, the software automatically calculates
the charge available to cues at each instant
and increases the firing pulse width for greater
reliability, particularly for parallel wiring.
The software also automatically calculates the
worst case voltage and compares it against your
planned e-match usage, and will automatically
split cues, or warn you if a configuration won't
work. When wiring in parallel, especially with
the 5-Ampere current limit, giving the e-matches
a longer firing pulse generates more energy
to fire them more reliably.
"I
have two firing panels with me at all times,
because it's not at all uncommon that if I had
a bad day and we have to run a bunch of continuity
tests, my batteries are gone by the time the
show starts -- and these are pretty big batteries.
Yours look even smaller. I don't want to have
to buy two of yours as well."
It's true that the battery technology powering
the Firelinx system is small. They're a new
battery technology with more power density and
more recharge cycles than any other battery.
We combine this with very low power electronics
and active power management, which automatically
powers down circuitry that isn't needed at the
moment, to extend the battery life even further.
We also constantly monitor battery levels, and
provide backup options - external line power
or external battery input - just in case. The
firing modules can actually go to "sleep"
for hours at a time, barely touching their battery
power. In this mode, they can last for days
in remote locations.
"I
know the e-match specification says all are
guaranteed to fire at 500mA, but as a pyro with
a long history, I make sure I can hit them with
at least an Amp just to be sure. Can you do
that?"
In
the firing module, we have set our specifications
to ensure that firing current stays above the
500mA minimum firing specification. If our capacitors
are not charged to at least 90% of their specified
value, we will notify the user of the problem
and he can change out the module. A 90% minimum
reading assures 1A of initial current, and current
above 500mA for the entire firing pulse width.
Some systems specify (check your manual) that
a 50% reading on the firing unit charge gauge
passes the charge test. This would equate to
a 12V firing charge, or initial current of only
600mA for 10 matches. It should work, but most
operators wouldn't trust that number if they
knew about it. By the end of the firing pulse
the current would be well below the 500mA minimum.
<<
Back to Wishlist